Customization: | Available |
---|---|
Movement Way: | Fixed |
Atomization: | Pressure Atomization |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Special configuration(can be optional):
1.Heating control
The oven can be equipped with Programmed cascade heating control instrument. It can be 30 segment program control, PID automatic adjustment.
2. Multiple channel paperless temperature recorder with thermocouple sensors.
It Can be U disk output, record storage.
Before you place the order, please indicate if you need the device.
Protection system:
1.Leakage protection
2.Circuit breaker protection
3.Motor overload protection
4.Grounding protection
5.Overtemperature protection
Model | Tray number | Heating Power (KW) |
Working temperature scope (ºC) |
Uniform temperature (ºC) |
Motor power (W) |
Working room size (mm) | Overall size (mm) |
H×W×D | H×W×D | ||||||
DYG-A | 5 | 9 | room~300 | ±2.5 | 180 | 1000×800×800 | 1558×1410×1050 |
DYG-B | 5 | 12 | room~300 | ±2.5 | 370 | 1000×1000×1000 | 1780×1360×1250 |
DYG-C | 8 | 15 | room~300 | ±2.5 | 750 | 1200×1000×1200 | 1980×1360×1450 |
DYG-D | 10 | 18 | room~300 | ±2.5 | 750 | 1500×1200×1000 | 2180×1560×1250 |
DYG-E | 10 | 21 | room~300 | ±2.5 | 1100 | 1500×1200×1200 | 2180×1560×1450 |
DYG-F | 10 | 24 | room~300 | ±2.5 | 1100 | 1500×1200×1500 | 2180×1560×1750 |